월성 압력관 통합지침 개발
정한섭 · 대한기계학회 춘추학술대회 · 2011
A life cycle management plan has been developed for Wolsong PTs. In-service-inspection of CSA N285.4 and an engineering core assessment based on CSA N285.8 should verify that the probability of pressure tube rupture is maintained below the allowable limit. It is anticipated that the design life of 210,000EFPH can be accomplished. The in-service-inspection includes measurement of geometric variation, volumetric examination of flaw, equivalent concentration of hydrogen dissolved in the PT, and material properties. A comprehensive comparison of Wolsong PTs with Canadian CANDUs indicated that the material property of Canadian PTs, on which the material properties suggested in CSA N285.8 had been developed, represents conservatively the materials properties of Wolsong PTs. Periodic revisions of the LCMP are important in order to update new revision of codes, accumulated ISI DB and plant experiences.