열처리로에서 가진연소기술의 적용성 평가
조한창, 조길원 · KOSCO SYMPOSIUM 논문집 · 2009
An experimental study was carried out in a real scale test furnace to investigate the performance, such as NOx emission, enhancement of heat transfer, uniformity of temperature, and etc, of oscillating combustion applied in radiant tube burner system. A oscillating controller with solenoid valve were designed and used. Two burners used in steel industry were tested in this study. The fuel, used commercial LPG in this study, was only oscillated using the oscillating controller with a solenoid valve. As oscillating combustion was applied in radiant tube burner system, it is found that NOx emission, compared to no oscillation, could be reduced by 20~30% at 2.5㎐ without CO emission. However, as oscillating frequency was increased, effect of abatement of NOx emission is gradually reduced. From the measurement of furnace heating time from 100℃ to 900℃, heat transfer is increased by 4.0% at the oscillation of 2㎐. Temperature distribution of radiant tube surface is more uniform at oscillation of 2Hz with decrease of the peak temperature and increase of low temperature. From these results, it is confirmed that oscillating combustion is useful in radiant tube burner system.
Cited by 1 works.