극 수 슬롯 조합과 운전 특성을 고려한 전기자동차용 IPM의 성능 특성에 관한 연구

서장호 · 한국자동차공학회 지회 학술대회 논문집 · 2013

This paper shows the characteristics of performance for interior permanent magnet machine (IPM) considering driving conditions such as maximum torque per ampere (MTPA) and flux-weakening control especially in terms of harmonic loss. In particular, based on finite element analysis (FEA), permanent magnet (PM) eddy-current loss and the harmonic iron loss have been computed where the models have been intentionally designed to identify effects of pole-slot combinations on the loss while maintaining the required power for electric vehicle. From the analysis results, it was shown that the rotor iron loss and PM eddy-current loss of machine employing fractional slot winding has extremely large at load condition. Furthermore, it was reveal that the harmonic iron loss at high-speed operation is mainly distributed stator teeth and rotor surface, which may aggravate cooling system of the rotor structure in the vehicle.