이어붓기 시공시 구획재 변화에 따른 콘크리트의 차단특성
한천구, 정덕우 · 대한건축학회 논문집 - 구조계 · 2005
This paper investigates experimentally blocking performance of concrete under various blocking material condition in consecutive placing. Blocking materials are used to block the concrete when unexpected termination of concrete placing occurs or placing zone is considered. Control concrete and high fluidity concrete(HFC) were made and two different W/B are chosen including 30% and 50%. When the gate opens, concrete with 30% of W/B and 21 cm of slump does not pass through the blocking materials until vibration is applied. After vibration is applied, large amount of concrete is passed through. On the other hand, when the gate opens, HFC with slump flow of 60cm passes through the blocking material even before vibration. Accordingly, while applying vibration, remarkable increase in passing amount of HFC is not found. the larger the slump and the gap between blocking bar and the size of metal lath is, the lower the blocking performance is. For the effect of diameter of blocking bars on the blocking performance, smaller diameter has better performance. The most favorable combination between diameter of blocking bar and gap between blocking bars is considered to be less than 20mm in gap and Φ10mm in diameter. Based on the results, the use of metal lath to block concrete exhibits superior to the use of blocking bar. Therefore, the use of metal lath with M5(32.5X62.5X3.2) can achieve desirable performance related to blocking performance of concrete.
Cited by 0 works.