겨울철과 여름철에서 기포펌프에 대한 비교분석 및 성능평가

이광성, 이설송, Waliur Rahaman et al. · 대한기계학회 춘추학술대회 · 2008

This study represents the performance evaluation and comparative analysis on the bubble pump in winter and summer. The experimental apparatus are consisted of bubble pump, solar collector and heat exchanger. In addition, the flow meter was installed at outlet of heat exchanger to obtain the temperature change. The complete system was instrumented to measure the pressure, flow-rates and temperature at several locations in winter and summer. As the results of experimental study, the average value of heat amount in heat exchanger was about max 10.64㎉/hr in clear day of winter and about max 6.88㎉/hr in clear day of summer. The maximum value of heat amount in water tank(0.4㎥) was about max 489.7㎉/hr in clear day of winter and about max 373.3㎉/hr in clear day of summer. The maximum value of mass flow rate in bubble pump was about max 0.5 l/min in clear day of winter and about max 0.4 l/min in clear day of summer.