열유속이 있는 난류 원관 유동에의 FLUENT의 2방정식 난류모델의 적용성 판단

문치명, 백성구, 박승오 · 2003

This paper assesses the two-equation turbulence models available in a commercial code, FLUENT, for heat transfer in a turbulent heated pipe flow. In case of flow under RED = 10, 000, Standard k-e and Realizable k-e models overpredict the Nusselt number about 20% compared with the experimental correlation, and RNG k-e model overpredicts about 30% when the two-layer zonal method is employed. When wall function method is adopted, all k-e models show better predictions. Standard k-ω and SST k-ω models have the dependency on the first grid point (0.3<y₁+<3). As Reynolds number becomes high, the predictions of all k-e and k-ω models are in a good agreement with the experimental correlation.