헬리컬 코일 관내의 비등열전달에 관한 실험적 연구
사용철, 이준식, 노승탁 · 대한설비공학회 학술발표대회논문집 · 1997
The charicteristics of the forced convective boiling heat transfer of R-113 in a coiled tube were investigated. A coiled tube of 10.9 ㎜ I.D with coil diameter of 0.332m was directly heated by AC. Experiments were conducted in the range of mass velocity of 300 to 900 ㎏/s, heat flux of 20 to 60 ㎾/㎡ and pressure of 0.2 to 0.8 Mpa. Heat transfer coefficient was highest at the coil outside and lowest at the inside except for low mass velocity. Average heat transfer coefficients in the nucleated boiling region were largly affected by the system pressure.
Cited by 0 works.