온실의 열에너지 흐름 모델링을 통한 지열히트펌프시스템 운전 시뮬레이션
류연수, 김진욱, 주혜진 · 한국태양에너지학회 춘계학술발표회 논문집 · 2013
We analyzed by comparing the simulation and the actual operation status for the operation and greenhouse internal temperature gradient due to the external temperature of geothermal heat pump system that installed in Gongjoo. The simulation results that base on data as operating of heating on December 14, 2011 in Winter season are as follows. 1) Thermal storage tank temperature of the simulation that base on calculating heat quantity and modeling as the same internal and external temperature conditions has risen a little more, but was similar as temperature of the actual operation. 2) In Gongjoo area, solar radiation per day from December 24, 2011 to January 31, 2012 was 1.85 MJ/㎡ ~ 14 MJ/㎡, average solar radiation was 9.065 MJ/㎡. We knew that heating load were adding because it was cloudy weather and solar radiation was 5.14MJ/㎡(57% of average) on December 14, 2011. 3) Because of the influence of solar radiation, it is essential for predictive control technique on reflecting of solar radiation elements of the daytime in Winter season.