태양열 해수담수화 시스템을 위한 저압 증발식 다중효용 담수기 성능연구
주홍진, 곽희열 · 대한설비공학회 학술발표대회논문집 · 2012
This study was accomplished to evaluate the performance of Multi Effect Distillation(MED) for solar thermal desalination system. It was designed Multi effect distillation with 3㎥/day capacity and Shell&Tube type heat exchanger. Also, The effective heat transfer of Shell&Tube heat exchanger was used Cu(90%)-Ni(10%) corrugated tube. The parameters relating to the performance of Multi Effect Distillation are known as hot water flow rate. The experimental conditions for each parameters were 18 ℃ for sea water inlet temperature, 6㎥/hour sea water inlet volume flow rate, 75 ℃ for hot water inlet temperature, 2.4, 3.6, and 4.8 ㎥/hour for hot water inlet volume flow rate, respectively. The results are as follows, Development for Multi effect distillation was required about 40kW heat and 35kW cooling source to produce 3㎥/day of fresh water. And, Performance ratio of Development Multi effect distillation was about 2.0191.