색변화에 따른 휘도측정기기의 정확도 검증 평가

공효주, 이영목, 임종민 · 2014

It is widely recognized that using a proper measuring device and establishing the correct way to measure are essential to reduce excess light pollution and create a pleasant light environment. To this end, the Ministry of Environment is considering the designation of an organization in charge of measuring and analyzing light pollution and the approval on model of measuring devices. Currently Korea divides light pollution largely into three categories such as architectural pole lighting, advertising lighting, and decorative lighting. Especially advertising lighting and decorative lighting are measured using various luminance measuring devices. Despite the diversity of luminance meters, the standards for structure and performance of measuring devices are not established yet. Therefore this study aims to verify and evaluate the error rates of luminance meters depending on lighting colors which is one of variables to evaluate luminance meters. For the research, the three luminance meter (point luminance meter, surface luminance instrument, recording luminance meter) was selected for measurement. the RGB and white colour of LED lighting is installed in the darkroom for validation. The findings showed that the reproducibility of luminance meters according to lighting colors was all high, but the error rate according to measurement periods was different. In other words, it is very important to use a correct luminance meter to properly measure light pollution. In addition, further studies for the error verification of luminance meters considering variables such as measurement angle, distance, and wavelength other than lighting color will be needed.

Cited by 0 works.

Authors