금속소재의 급속가열을 위한 순산소 직화가열설비의 적용특성 평가

조한창, 오혁진, 조길원 · KOSCO SYMPOSIUM 논문집 · 2010

A study has been carried out to evaluate the performance of a commercial DFI (direct flame impingement) booster and to reduce the temperature difference along the strip width. The evaluation is accomplished by the analyses of NOx emissions, temperature rising of the strip and temperature difference along the strip width. The strip conditions (width and thickness), line speed and the flow rates of LNG and oxygen play a very important role. These operating conditions are controlled, and the strip temperature is measured using thin thermocouples located at the DFI inlet and outlet. It is found that the thermal efficiency of the DFI booster is lower than 57%. The strip temperature in the walk side is lower than that in the drive side due to the direction of the flue gas exhaust. High NOx emissions are measured because of the nitrogen used for the burner cooling Finally, the solutions for these problems discovered during the test operation are suggested.

Cited by 0 works.