Технология паттерной лазеркоагуляции при задней агрессивной ретинопатии недоношенных

Alexander V. Tereshchenko, Ю. А. Белый, P.L. Volodin · Кубанский научный медицинский вестник · 2011

13 infants (26 eyes) underwent pattern retinal lasercoagulation with use of semiautomated scanning laser ophthalmocoagulator (group 1). 12 infants (24 eyes) underwent standard retinal lasercoagulation by single applications with use of diode laser (group 2). The duration of lasercoagulation was 15 minutes at the average in group 1 and 40 minutes in group 2. Stable regress of AP-ROP was achieved in 77% cases in group 1 and in 71% cases in group 2.

Cited by 0 works.