광원의 파장 분포와 조도에 따른 시환경의 주관적 반응 평가 및 건물에너지 소비
김효인, 윤근영 · 대한설비공학회 하계학술발표회 논문집 · 2012
This study aims to reveal occupant’s the subjective response in accordance to the illuminance, SPD and control range of lighting and reduce the energy consumption of a building by maintaining the quality of visual environment. The experiment was carried out to investigate overall evaluation, preference, atmosphere, satisfaction of the different visual environment. The building simulation tool, DesignBuilder, was used to estimate the building energy consumption. The evaluation score was higher under the highest SPD condition(636nm) compare to the low SPD condition (453nm). If the illuminance was 573lx or above under the highest SPD conditions, the results were similar to the existing lighting system, a fluorescent lamp, is used, or a higher score. In conclusion, when the visual comfort conditions(SPD peak of 636nm, illuminance 573lx) is applied, 10% of building energy consumption could be reduced compare to the existing lighting system.