This study investigated the wear of the valve and seat insert seating faces. A tester, an exhaust valve and a seat insert were used. Test variables were cycle numbers (2×10?, 4×10?, 6×10? and 8×10?) and ㎐ (10㎐ and 25㎐). The other test conditions such as temperature (350℃), fuel (LPG) and load (1960N) were fixed. The 10㎐ tests indicated that the average Rmax of the valve increased at the rate of 7.76㎛/10? cycles starting from 29.42㎛ at the 2×10? cycles and that of the seat insert increased at the rate of 8.57㎛/10? cycles starting from 34.19㎛ at the 2×10? cycles. The 25㎐ tests indicated that the average Rmax of the valve increased at the rate of 1.58㎛/10? cycles starting from 74.2㎛ at the 2×10? cycles and that of the seat insert increased at the rate of 1.25㎛/10? cycles starting from 83.95 ㎛ at the 2×10? cycles. The tribochemical reaction product covered the two seating faces, preventing the wear of the seating faces. As cycle numbers became greater, the average Rmax of the seating faces became greater, but the increase rate varied significantly depending on the ㎐. The wear mechanism of the two faces was investigated through the tribochemical reaction.