Инфракрасная термометрия предлежащей части головы плода в потужном периоде родов как метод диагностики гипоксически-ишемических поврежденеий головного мозга

А. Л. Ураков, Н. А. Уракова · Современные проблемы науки и образования · 2012

Held infrared monitoring of the fetal presenting part of the head of the fetus in the process of labor in 20 women with physiological pregnancy and the 15 pregnant with the presence of placental insufficiency and low prenatal resistance to fetal hypoxia. Shows the difference heat the surface of the presenting part of the head of the fetus in the normal course of labor and in hypoxia of the fetus. The way of assessing oxygen and/or arterial insufficiency of the brain of the fetus in the bearing-down stage of labor, which allows to exclude neonatal asphyxia in labor. The essence of the method reduces to the continuous infrared thermometry of the skin of the visible part of the head after her baby´s teething, and radiant heat to the definition of the difference over the bones of the skull and in the projection of the gap between them. When a local or elimination of hypothermia in the projection area of the bone gap issue a conclusion about the absence or the presence of oxygen and/or arterial insufficiency of the cerebral cortex of the fetus.

Cited by 0 works.

Authors