수정된 등가골조법을 이용한 포스트 텐션 플랫 플레이트 골조의 해석

박영미, 이재주, 한상환 · 대한건축학회 학술발표대회 논문집 - 구조계 · 2009

In general, Post-Tensioned (PT) flat plate systems have been used as a gravity load resisting system (GLRS) with lateral force resisting system (LFRS) such as shear walls. Thus, GLRS should retain the ability to undergo the lateral drift associated with the LFRS without loss of gravity load carrying capacity. PT flat plate system should be considered internal forces (e.g., unbalanced moments) and lateral deformation generated in vicinity of slab joints render the system more susceptible to punching shear. ACI 318(2008) permits the finite-element method, effective beam width method, and equivalent frame method for flat plate systems under lateral loads. These analysis methods can produce widely different result, and each has advantage and disadvantages. Thus, it is sometimes difficult for a designer to select an appropriate analysis method and interpret the results for design purposes. This study is to verify practicality of the modified equivalent frame method for PT flat plate system under lateral loads. To verify, this study compared analysis results using the modified equivalent frame method with published experimental results of PT flat plate system.