수평가진 시스템의 열 특성 및 모멘트 성능 검증
은희광, 임종민, 문상무 et al. · 항공우주기술 · 2009
Shaker system is used to simulate the vibration from the launch environment The vibration tests are performed in the vertical and lateral direction. For the lateral vibration test, the slip table system is used with shaker system. For the latest large satellite, vibration test adaptor is made of the steel. But slip table of lateral vibration is made of magnesium, so there is big difference of thermal expansion ratio between slip table and vibration test adaptor. This paper encompasses the following items; verification process of thermal characteristics and overturning moment and a solution for lateral vibration test with steel vibration test adaptor.
Cited by 0 works.