실측데이터를 활용한 감육배관 평가식의 두께 기준 비교

이정근, 박치용, 이성호 et al. · 대한기계학회 춘추학술대회 · 2005

Local wall thinning by the flow accelerated corrosion is one of important factors for the integrity features of the nuclear power plant. So many researches have been followed and various evaluation criteria also have been proposed. In this study, comparison of the evaluation criteria of the thinned pipes by wall thickness was performed. Measured data from the nuclear power plant were applied for this comparison. And analyzed data by evaluation criteria were compared with each evaluation criteria by thickness of the pipe. From this comparison, the construction code for the nuclear power plant has enough margins for local wall thinning on the pipe thickness view. And the owner of the nuclear power plant can choose the suitable evaluation criteria as more economic and safety point of view.

Cited by 0 works.