압력감응페인트를 이용한 확대/축소 유로에서의 막냉각 효율 측정
박승덕, 이기선, 김성하 et al. · The KSFM Journal of Fluid Machinery · 2008
Film cooling effectiveness on the convergent or divergent channel was measured by pressure sensitive paint technique. The channel convergent or divergent angle was changed from -5° to 10° and the tested blowing ratios were 0.5, 1 and 2. Results showed that the film cooling effectiveness on the convergent channel was not much affected by the convergent angle. With divergent film cooled surface, the film cooling effectiveness near the injection hole decreased as the divergent angle increases. However, the film cooling effectiveness at far downstream from the hole showed opposite trend. For the non-film cooled surface inclined case, the film cooling effectiveness was not much affected by the divergent angle.
Cited by 0 works.