Implementation of on-line data reduction algorithms in the CMS Endcap Preshower Data Concentrator Cards
David C. Barney, W Bialas, P. Kokkas et al. · Journal of Instrumentation · 2007
The CMS Endcap Preshower (ES) sub-detector comprises 4288 silicon sensors, each containing 32 strips. The data are transferred from the detector to the counting room via 1208 optical fibres running at 800Mbps. Each fibre carries data from two, three or four sensors. For the readout of the Preshower, a VME-based system, the Endcap Preshower Data Concentrator Card (ES-DCC), is currently under development. The main objective of each readout board is to acquire on-detector data from up to 36 optical links, perform on-line data reduction via zero suppression and pass the concentrated data to the CMS event builder. This document presents the conceptual design of the Reduction Algorithms as well as their implementation in the ES-DCC FPGAs. These algorithms, as implemented in the ES-DCC, result in a data-reduction factor of 20.
Cited by 5 works. doi:10.1088/1748-0221/2/03/p03001 Open-access PDF
Authors
References
- S-LINK, a data link interface specification for the LHC era
- Receiver ASIC for timing, trigger and control distribution in LHC experiments
- G-link and gigabit Ethernet compliant serializer for LHC data transmission
- A CMOS low power, quad channel, 12 bit, 40MS/s pipelined ADC for applications in particle physics calorimetry
- PACE3 : A large dynamic range analog memory ASIC assembly designed for the readout of silicon sensors in the LHC CMS Preshower
- An efficient hardware design for rejecting common mode in a group of adjacent channels of silicon microstrip sensors used in high energy physics experiments