Nonlinear Data Alignment for UPLC−MS and HPLC−MS Based Metabolomics: Quantitative Analysis of Endogenous and Exogenous Metabolites in Human Serum
Anders Nordström, Grace O’Maille, Chuan Qin et al. · Analytical Chemistry · 2006
A nonlinear alignment strategy was examined for the quantitative analysis of serum metabolites. Two small-molecule mixtures with a difference in relative concentration of 20-100% for 10 of the compounds were added to human serum. The metabolomics protocol using UPLC and XCMS for LC-MS data alignment could readily identify 8 of 10 spiked differences among more than 2700 features detected. Normalization of data against a single factor obtained through averaging the XCMS integrated response areas of spiked standards increased the number of identified differences. The original data structure was well preserved using XCMS, but reintegration of identified differences in the original data reduced the number of false positives. Using UPLC for separation resulted in 20% more detected components compared to HPLC. The length of the chromatographic separation also proved to be a crucial parameter for a number of detected features. Moreover, UPLC displayed better retention time reproducibility and signal-to-noise ratios for spiked compounds over HPLC, making this technology more suitable for nontargeted metabolomics applications.
Cited by 273 works. doi:10.1021/ac060245f
Authors
References
- Statistical significance for genomewide studies
- Metabolite profiling for plant functional genomics
- Identifying differentially expressed genes using false discovery rate controlling procedures
- An integrated method for spectrum extraction and compound identification from gas chromatography/mass spectrometry data
- Chromatographic alignment by warping and dynamic programming as a pre-processing tool for PARAFAC modelling of liquid chromatography–mass spectrometry data
- Processing methods for differential analysis of LC/MS profile data
- High Resolution “Ultra Performance” Liquid Chromatography Coupled to oa-TOF Mass Spectrometry as a Tool for Differential Metabolic Pathway Profiling in Functional Genomic Studies
- Metabonomics: the use of electrospray mass spectrometry coupled to reversed‐phase liquid chromatography shows potential for the screening of rat urine in drug development
- High-speed peak matching algorithm for retention time alignment of gas chromatographic data for chemometric analysis
- Ultra‐performance liquid chromatography coupled to quadrupole‐orthogonal time‐of‐flight mass spectrometry