OBJECTIVE: The purpose of our study was to evaluate whether a computer-aided diagnosis (CAD) scheme can assist radiologists in distinguishing small benign from malignant lung nodules on high-resolution CT (HRCT). MATERIALS AND METHODS: We developed an automated computerized scheme for determining the likelihood of malignancy of lung nodules on multiple HRCT slices; the likelihood estimate was obtained from various objective features of the nodules using linear discriminant analysis. The data set used in this observer study consisted of 28 primary lung cancers (6-20 mm) and 28 benign nodules. Cancer cases included nodules with pure ground-glass opacity, mixed ground-glass opacity, and solid opacity. Benign nodules were selected by matching their size and pattern to the malignant nodules. Consecutive region-of-interest images for each nodule on HRCT were displayed for interpretation in stacked mode on a cathode ray tube monitor. The images were presented to 16 radiologists-first without and then with the computer output-who were asked to indicate their confidence level regarding the malignancy of a nodule. Performance was evaluated by receiver operating characteristic (ROC) analysis. RESULTS: The area under the ROC curve (Az value) of the CAD scheme alone was 0.831 for distinguishing benign from malignant nodules. The average Az value for radiologists was improved with the aid of the CAD scheme from 0.785 to 0.853 by a statistically significant level (p = 0.016). The radiologists' diagnostic performance with the CAD scheme was more accurate than that of the CAD scheme alone (p < 0.05) and also that of radiologists alone. CONCLUSION: CAD has the potential to improve radiologists' diagnostic accuracy in distinguishing small benign nodules from malignant ones on HRCT.
Cited by 97 works. doi:10.2214/ajr.183.5.1831209
Authors
- Feng Li
- Masahito Aoyama
- Junji Shiraishi
- Hiroyuki Abé
- Kenji Suzuki
- Roger M. Engelmann
- Shusuke Sone
- Heber MacMahon
- Kunio Doi
References
- Early Lung Cancer Action Project: overall design and findings from baseline screening
- Mass screening for lung cancer with mobile spiral computed tomography scanner
- Peripheral lung cancer: screening and detection with low-dose spiral CT versus radiography.
- Maximum likelihood estimation of receiver operating characteristic (ROC) curves from continuously-distributed data
- Screening for Lung Cancer with Low-Dose Spiral Computed Tomography
- CT Screening for Lung Cancer
- Receiver Operating Characteristic Rating Analysis
- The Probability of Malignancy in Solitary Pulmonary Nodules
- Screening for Early Lung Cancer with Low-Dose Spiral CT: Prevalence in 817 Asymptomatic Smokers
- Solitary pulmonary nodule: high-resolution CT and radiologic-pathologic correlation.