Exploring Key Parameters to Detect Subtle Ligand-Induced Protein Conformational Changes Using Traveling Wave Ion Mobility Mass Spectrometry
Cédric Atmanène, Stéphanie Petiot-Bécard, Denis Zeyer et al. · Analytical Chemistry · 2012
Evidencing subtle conformational transitions in proteins occurring upon small modulator binding usually requires atomic resolution techniques (X-ray crystallography or NMR). Recently, hyphenation of ion mobility and mass spectrometry (IM-MS) has greatly enlarged the potentials for biomolecular assembly structural characterization. Using the well 3D-characterized Bcl-xL/ABT-737 protein model, we explored in the present report whether IM-MS can be used to differentiate close conformers and monitor collision cross section (CCS) differences correlating with ligand-induced conformational changes. Because comparing CCS derived from IM-MS data with 3D-computed CCS is critical for thorough data interpretation, discussing pitfalls related to protein construct similarity and missing sequence sections in PDB files was of primary importance to avoid misinterpretation. The methodic exploration of instrument parameters showed enhanced IM separation of Bcl-xL conformers by combining high wave heights and velocities with low helium and nitrogen flow rates while keeping a high He/N(2) flow rate ratio (>3). The robustness of CCS measurements was eventually improved with a modified IM calibration method providing constant CCS values regardless of instrument settings. Altogether, optimized IM-MS settings allowed a 0.4 nm(2) increase (i.e., 2%) of Bcl-xL CCS to be evidenced upon ABT-737 binding.
Cited by 30 works. doi:10.1021/ac203223h
Authors
References
- X-ray and NMR structure of human Bcl-xL, an inhibitor of programmed cell death
- Structural Information from Ion Mobility Measurements: Effects of the Long-Range Potential
- The observation of non-covalent interactions in solution by electrospray ionization mass spectrometry: Promise, pitfalls and prognosis
- Observation of the heme-globin complex in native myoglobin by electrospray-ionization mass spectrometry
- Detection of noncovalent receptor-ligand complexes by mass spectrometry
- An exact hard-spheres scattering model for the mobilities of polyatomic ions
- Ion mobility–mass spectrometry analysis of large protein complexes
- Evidence for Macromolecular Protein Rings in the Absence of Bulk Water
- Quantitative determination of noncovalent binding interactions using soft ionization mass spectrometry
- Collision Cross Sections of Proteins and Their Complexes: A Calibration Framework and Database for Gas-Phase Structural Biology