Virtual Elastic Sphere Processing Enables Reproducible Quantification of Vessel Stenosis at CT and MR Angiography
Felix Gremse, Christoph Grouls, Moritz Palmowski et al. · Radiology · 2011
PURPOSE: To develop and evaluate a user-friendly tool to enable efficient, accurate, and reproducible quantification of blood vessel stenosis in computed tomographic (CT) and magnetic resonance (MR) angiographic data sets. MATERIALS AND METHODS: All clinical experiments were approved by the institutional review board, and informed patient consent was acquired. Animal experiments were approved by the governmental review committee on animal care. A virtual elastic sphere passes through a blood vessel specified by user-provided start and end points, and the adapting diameter over the course of the vessel is recorded. The program was tested in phantoms to determine the accuracy of diameter estimation, and it was applied in micro-CT data sets of mice with induced vessel stenosis. Dual-energy CT angiography and MR angiography were performed in 16 patients with carotid artery stenosis, and reproducibility and required reader time of this automated technique were compared with manual measurements. Additionally, the effect of dual-energy CT-based discrimination between iodine- and calcium-based enhancement was investigated. Differences between carotid artery diameters of mice and between automated and manual measurement durations were assessed with a paired t test. Reproducibility of stenosis scores was evaluated with the Fisher z test. RESULTS: Phantom diameters were determined with an average error of 0.094 mm. Diameters of normal and injured carotid arteries of mice were significantly different (P < .01). For patient data, automated interreader variability was significantly (P < .01) lower than manual intra- and interreader variability, while time efficiency was improved (P < .01). CONCLUSION: The virtual elastic sphere tool is applicable to CT, dual-energy CT, and MR angiography, and it improves reproducibility and efficiency over that achieved with manual stenosis measurements.
Cited by 36 works. doi:10.1148/radiol.11110069
Authors
- Felix Gremse
- Christoph Grouls
- Moritz Palmowski
- Twan Lammers
- Anke de Vries
- Holger Grüll
- Marco Das
- Georg Mühlenbruch
- Shamima Akhtar
- Andreas Schober
- Fabian M. Kiessling
References
- Beneficial Effect of Carotid Endarterectomy in Symptomatic Patients with High-Grade Carotid Stenosis
- Randomised trial of endarterectomy for recently symptomatic carotid stenosis: final results of the MRC European Carotid Surgery Trial (ECST)
- North American Symptomatic Carotid Endarterectomy Trial. Methods, patient characteristics, and progress.
- Analysis of pooled data from the randomised controlled trials of endarterectomy for symptomatic carotid stenosis
- How to measure carotid stenosis.
- Improved dual‐energy material discrimination for dual‐source CT by means of additional spectral filtration
- Partial carotid ligation is a model of acutely induced disturbed flow, leading to rapid endothelial dysfunction and atherosclerosis
- Identification, prognosis, and management of patients with carotid artery near occlusion.
- New Techniques in CT Angiography
- Quantification of carotid stenosis on CT angiography.