고온용 판-휜 열교환기 개발

곽재수, 안원근, 김형모 et al. · 대한기계학회 춘추학술대회 · 2005

Performance tests of the plate-fin type heat exchanger for high temperature application have been performed with a high temperature heat exchanger performance test facility. The facility consists of air compressor, electric heaters, venturi flow meters, flow control valves, and combination probes which can measure temperature, total and static pressures at the same time. The performance tests were carried out near the heat exchanger design condition and off-design conditions, and the test results were compared with the calculated results. The test results showed lower heat exchanging efficiency and smaller pressure drop than the calculated results. Based on the difference, the modified design of the heat exchanger was offered.

Cited by 0 works.