쓰레기자동집하시설의 악취저감대책에 대한 고찰
백경일, 엄진석, 나형용 et al. · 2014
The method of residential waste and food waste collecting is changed into automatic waste collection(AWC) system from direct collection by human resource. To solve the problem caused by odour from AWC facilities, the structure of input facilities, conveying pipes and collecting facilities have been changed into closed and sealed construction to enclosed the facilities and collect odour efficiently. Based on cases and experiences, to treat variable odour matters which are caused by food waste, chemical cleaning method is preferable method to cope with odour caused by food waste.
Cited by 7 works.