복합십자형 다이아프램으로 보강한 CFT 기둥-보 접합부의 내진성능 향상에 관한 실험적 연구
정도섭, 최성모, 김진호 et al. · 대한건축학회 학술발표대회 논문집 - 구조계 · 2004
The purpose of this paper is to improvement the Combined Cross Diaphragm which was developed previously, to developed Concrete Filled tubular Square Column-to-Beam Connections which can use on strong earthquake region, and to evaluate the connection. Two full-scale specimens were tested according to the standard ANSI/AISC SSPEC-2002. in previously test, connections with combined cross diaphragm has 0.02rad. of inelastic rotational degree. It is degree of the connection what has the resistance against seismic performance required in the region of light/moderate earthquakes. In the result of test, combined cross diaphragm specimens reach 0.03rad. of inelastic rotational degree what can be used in the region of special earthquakes without stress concentration phenomenon of beam flange.
Cited by 0 works.