Hybrid Small Animal Imaging System Combining Magnetic Resonance Imaging With Fluorescence Tomography Using Single Photon Avalanche Diode Detectors
Florian Stuker, Christof Baltes, Katerina Dikaiou et al. · IEEE Transactions on Medical Imaging · 2011
The high sensitivity of fluorescence imaging enables the detection of molecular processes in living organisms. However, diffuse light propagation in tissue prevents accurate recovery of tomographic information on fluorophore distribution for structures embedded deeper than 0.5 mm. Combining optical with magnetic resonance imaging (MRI) provides an accurate anatomical reference for fluorescence imaging data and thereby enables the correlation of molecular with high quality structural/functional information. We describe an integrated system for small animal imaging incorporating a noncontact fluorescence molecular tomography (FMT) system into an MRI detector. By adopting a free laser beam design geometrical constraints imposed by the use of optical fibers could be avoided allowing for flexible fluorescence excitation schemes. Photon detection based on a single-photon avalanche diode array enabled simultaneous FMT/MRI measurements without interference between modalities. In vitro characterization revealed good spatial accuracy of FMT data and accurate quantification of dye concentrations. Feasibility of FMT/MRI was demonstrated in vivo by simultaneous assessment of protease activity and tumor morphology in murine colon cancer xenografts.
Cited by 75 works. doi:10.1109/tmi.2011.2112669
Authors
- Florian Stuker
- Christof Baltes
- Katerina Dikaiou
- Divya Vats
- Lucio Carrara
- Edoardo Charbon A
- Jorge Ripoll
- Markus Rudin
References
- Principles of Computerized Tomographic Imaging
- Fluorescence molecular tomography resolves protease activity in vivo
- Experimental three-dimensional fluorescence reconstruction of diffuse media by use of a normalized Born approximation
- multifunctional enzymes in cancer
- Design and characterization of a CMOS 3-D image sensor based on single photon avalanche diodes
- Performance evaluation of the microPET P4: a PET system dedicated to animal imaging
- In vivo imaging of proteolytic enzyme activity using a novel molecular reporter.
- X-ray-based attenuation correction for positron emission tomography/computed tomography scanners
- Performance test of an LSO-APD detector in a 7-T MRI scanner for simultaneous PET/MRI.
- Near-Infrared Optical Imaging of Protease Activity for Tumor Detection