Wall thinning defect due to flow-accelerated corrosion (FAC) is one of the degradation mechanisms of carbon steel piping components in nuclear power plant (NPP), and it results in reducing load carrying capacity and fatigue resistance of the piping components. Especially, the wall-thinning defect leads to abrupt rupture of piping components under normal operating pressure. Thus, it is important to accurately evaluate the failure pressure of piping components containing an internal wall-thinning defect for ensuring integrity of piping system of NPP. Therefore, this study performed failure tests using real-scale elbows containing simulated wall-thinning defect under internal pressure and bending moment. Based on the results of experiments, the effect of circumferential thinning angle and bending moment on the failure pressure was investigated.