pH 용액 노출조건에 의한 지오텍스타일의 장기성능 평가

김수경, 안승재, 전한용 · 한국지반신소재학회 학술발표회 · 2012

In this study, index tests were conducted through the chemical resistance. Woven PET 5 ton/m and nonwoven PET 530g/m 2 geotextiles are subjected to the test. The chemical resistance test used pH 3, 5, 8, 12 buffer solution and tested at room temperature, 30℃, 50℃, 80℃. And the tensile strength was measured for 15days cycle. Test results based on data obtained by using Arrhenius equation to predict long-term performance of goetextiles and life were evaluated. As a result, the higher pH buffer solution and the higher temperature tends to decrease the tensile strength.

Cited by 2 works.