차량 충돌에 의한 기둥의 콘크리트 기초 접합부 거동 평가
강현구, 김진구 · 한국콘크리트학회논문집 · 2014
Structures are often subject to vehicle collision which can be accidental or terrorist attack. Previous research shows that the damage in major columns may result in progressive collapse of a whole building. This study investigates the performance of a steel column standing on a reinforced concrete footing subjected to a vehicle collision. The size and the axial load of the steel column are determined based on the assumption that it is the first story corner column in a typical three-story building with six meter span length. The finite element model of a eight-ton single unit truck provided by the NCAC (National Crash Analysis Center) is used in the numerical analysis. The finite element analysis is performed using the LS- DYNA, and the results show that the behavior of the column subjected to car impact depends largely on the column-foundation connection detail.
Cited by 1 works.