Evaluation of various deformable image registration algorithms for thoracic images
Noriyuki Kadoya, Y. Fujita, Yoshiyuki Katsuta et al. · Journal of Radiation Research · 2013
We evaluated the accuracy of one commercially available and three publicly available deformable image registration (DIR) algorithms for thoracic four-dimensional (4D) computed tomography (CT) images. Five patients with esophagus cancer were studied. Datasets of the five patients were provided by DIR-lab (dir-lab.com) and consisted of thoracic 4D CT images and a coordinate list of anatomical landmarks that had been manually identified. Expert landmark correspondence was used for evaluating DIR spatial accuracy. First, the manually measured displacement vector field (mDVF) was obtained from the coordinate list of anatomical landmarks. Then the automatically calculated displacement vector field (aDVF) was calculated by using the following four DIR algorithms: B-spine implemented in Velocity AI (Velocity Medical, Atlanta, GA, USA), free-form deformation (FFD), Horn-Schunk optical flow (OF) and Demons in DIRART of MATLAB software. Registration error is defined as the difference between mDVF and aDVF. The mean 3D registration errors were 2.7 ± 0.8 mm for B-spline, 3.6 ± 1.0 mm for FFD, 2.4 ± 0.9 mm for OF and 2.4 ± 1.2 mm for Demons. The results showed that reasonable accuracy was achieved in B-spline, OF and Demons, and that these algorithms have the potential to be used for 4D dose calculation, automatic image segmentation and 4D CT ventilation imaging in patients with thoracic cancer. However, for all algorithms, the accuracy might be improved by using the optimized parameter setting. Furthermore, for B-spline in Velocity AI, the 3D registration error was small with displacements of less than ∼10 mm, indicating that this software may be useful in this range of displacements.
Cited by 107 works. doi:10.1093/jrr/rrt093 Open-access PDF
Authors
- Noriyuki Kadoya
- Yoshiyuki Katsuta
- Suguru Dobashi
- Kazuma Kishi
- Masaki Kubozono
- Rei Umezawa
- T. Sugawara
- Haruo Matsushita
- Keiichi Jingu
References
- Determining optical flow
- Determining Optical Flow
- On the limited memory BFGS method for large scale optimization
- Image matching as a diffusion process: an analogy with Maxwell's demons
- Medical image registration
- Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy
- PET-CT image registration in the chest using free-form deformations
- Validation of an accelerated ‘demons’ algorithm for deformable image registration in radiation therapy
- 4-dimensional computed tomography imaging and treatment planning
- A framework for evaluation of deformable image registration spatial accuracy using large landmark point sets