마이크로 모세관 유동에서 점도에 따른 계면 이동 연구

성재용, 이석종, 신평호 · 한국생산제조학회 학술발표대회 논문집 · 2008

In this paper we describe an experimental method and an image processing technique for detecting the position of a meniscus in the micro capillary flows. The flow times of the meniscus in both cases of the ethylene glycol and glycerine were evaluated at the same temperature and position from the entrance of capillary tube. Physical properties of ethylene glycol and glycerine such as viscosity, surface tension, contact angle, which significantly impact on capillary force, were measured. As a result, it was found that a big change of viscosity and contact angle strongly influenced on the flow time inside the micro capillary tube.