Температурный режим в кожухе газоперекачивающего агрегата
Ali V. Aliev, Евгений Васильевич Мерзляков · 2014
Experiments showed that in standard gas-distributing units (GPA) temperature of an external surface of cases of the compressor of a high pressure can make from 140 °C to 340 °C, an external surface of the combustion chamber and the turbine of a high pressure - from 490 °C to 550 °C, etc. The total thermal emission from the engine taking into account leaks during the work on a nominal mode can make more than 1,0 MWt of flowing part. The temperature mode in GTU vicinity substantially depends on temperature and character of a current of cooling air in subframe space of GTU (under a floor 3 KShT) as natural convection of air in KShT leads to movement of heated gas up in the vertical direction. In article the questions connected with definition of a temperature mode in a casing of the working gas-distributing unit (GDU) are considered. Is established that the main factors, having impact on a temperature mode in GPA casing, GTU which were formed in subframe space stagnant zones and zones of returnable currents of cooling air are. Research of ways of decrease in air temperature in subframe space of GTU and in GPA casing is executed by change of configuration of its units. The solution of a task is carried out in spatial gasdynamic statement with use of numerical methods
Cited by 0 works. doi:10.17122/ngdelo-2014-1-137-140