파랑하중을 고려한 초대형 부유식 구조물의 반강접 접합부 동적해석
김우년, 송화철 · 대한건축학회 학술발표대회 논문집 - 구조계 · 2004
The additional moment due to wave loads occurs because the superstructures of very large floating structures(VLFS) are influenced by wave loads instead of earthquake loads. In order to reduce the additional moment, this study used the semi-rigid connections which lie between fully rigid and pinned. If semi-rigid connections are used for superstructures of VLFS, the moment of beams can be reduced and more economical construction will be possible. In this study, by analyzing the time history responses of superstructures, the dynamic behavior of rigid connection is compared with that of semi-rigid connection in consideration of static loads (Dead, Live, Wind), wave loads and combination loads for a four-bay, three-story frame. The semi-rigid connection type is a steel tubular column with square external-diaphragm connections.