압축기 주변 유동의 활성화를 위한 유동 분배에 관한 연구
성봉길, 김재원 · 한국자동차공학회 춘 추계 학술대회 논문집 · 2005
An effort for enriched flows is made by considering flow balance in system. The present model is come from the cooling system of a refrigerator that includes a compressor, a coil-condenser and an axial flow fan for a forced blowing. The geometric arrangement of all components is fixed. However, the size and the position of both the inlet and outlet ports could be modified for the improved flow distribution around the compressor requires large flow rates for the effective cooling. The main methodology is PIV measurements of the flows inside the chamber. The optimal sizes and locations of the inlet and outlet grill are found by the comparisons of the flow profiles around the compressor. In addition the unwanted reverse flow is happened for the case of unbalanced inflow and outflow situation. The improved model shows the pronounced flow rate increasement around a compressor. The improved system is realized by the modified inlet ports with balanced outlet.