Clinical dose–volume histogram analysis for pneumonitis after 3D treatment for non-small cell lung cancer (NSCLC)
Mary V. Graham, James A. Purdy, Bahman Emami et al. · International Journal of Radiation Oncology*Biology*Physics · 1999
Cited by 1,223 works. doi:10.1016/s0360-3016(99)00183-2
Authors
- Mary V. Graham
- James A. Purdy
- Bahman Emami
- William B. Harms
- Walter R. Bosch
- Mary Ann Lockett
- Carlos A. Perez
References
- BMDP Statistical Software 1981.
- Tolerance of normal tissue to therapeutic irradiation
- Fitting of normal tissue tolerance data to an analytic function
- Calculation of complication probability factors for non-uniform normal tissue irradiation: The effective volume method gerald
- Histogram reduction method for calculating complication probabilities for three-dimensional treatment planning evaluations
- Radiation pneumonitis as a function of mean lung dose: an analysis of pooled data of 540 patients
- Dose-volume histogram and 3-D treatment planning evaluation of patients with pneumonitis
- Estimation of pneumonitis risk in three-dimensional treatment planning using dose-volume histogram analysis
- Physical and biological predictors of changes in whole-lung function following thoracic irradiation
- Applied Respiratory Physiology