과냉수 내부 슈평튜브 외면에서의 국소 풀비등 열전달계수

강명기 · 대한기계학회 춘추학술대회 · 2005

Subcooled pool boiling of water has been tested at atmospheric pressure to determine local heat transfer coefficients on the outside surface of a horizontal tube of 51 ㎜ diameter. The local values were determined at every 45˚ from the very bottom to the uppermost of the tube periphery and a representative value was suggested. The maximum and the minimum local coefficients were observed at the azimuthal angles of 45˚ and 180˚, respectively, from the tube bottom. The representative value was at the azimuthal angle of 90˚. The major mechanisms affecting the heat transfer on a horizontal tube were liquid agitation generated by the sliding bubbles and bubble coalescence.

Cited by 2 works.