라만 측정법을 이용한 알루미늄 파이프의 잔류응력 평가
Min Seong Kang, 김상영, 박수 et al. · 대한기계학회 춘추학술대회 · 2009
A straight pipe is used after complicated bending work in a mechanical system. In this work process, the plastic deformation of the pipe produces residual stress in the pipe. This residual stress significantly affects the behavior of pipe fracture. For this reason, residual stress must be evaluated. Measuring the residual stress of a U-shaped pipe is difficult with existing destructive and nondestructive measurement methods. In this paper, the residual stress of a U-shaped aluminum pipe (99.7% pure aluminum) was evaluated from the Raman shift by Raman spectroscopy and FEM analysis. The results of the stiffness test by FEM analysis are compared with those by experiments. The analyzed results of the Raman spectra showed a similar tendency with the results of the FEM analysis with respect to the residual stress distributions in U-shaped pipes. Also, the results of the bending tests showed resemblance to each other.
Cited by 0 works.