목업 테스트를 통한 창호 종류별 창호 결로방지 성능 평가방법

유지용, 이규남, 김영탁 et al. · 한국태양에너지학회 추계학술발표회 논문집 · 2012

In this study, we validated and analyzed the performance evaluation methods of the condensation prevention on the window through mock-up tests. NFRC 500-2010 compares the condensation prevention performance of various windows by using condensation resistance value at specific indoor temperature(21℃) and humidity(30%/50%/70%). AAMA 1503-09 is advantageous to the evaluation of condensation prevention performance for the overall window, while KS F 2295 is advantageous to the evaluation considering the local parts of the window. The results show that high-performance glazing type is Low-e (Argon filled), followed by Low-e (Air filled) and conventional double glazing. Based on the results of this study, we will establish the evaluation method which is appropriate to the domestic circumstances and users performance requirements.

Cited by 0 works.