장대형 터널 내 제트 팬 위치에 따른 환기해석

강신형, 변주석, 이진호 · 대한설비공학회 학술발표대회논문집 · 2007

This paper studies the ventilation characteristics according to the jet fan location at the long road tunnel using the CFD software ‘FLUENT’ which is based on the finite volume method. The tunnel model used in the analysis has a length of 1600 m, a cross sectional area of 120㎥, and is composed of 3 lanes and one way. The velocity profile, the distribution of CO concentration and the ventilation flow rate within the tunnel are analyzed, respectively. In the analysis, it is found that the dependence of the ventilation flow rate upon the jet fan location is small, but the CO concentration in the tunnel is at the lowest when the jet fans are installed near the tunnel outlet. An air stream right below the jet fan is almost inactive due to the strong stream injection near the jet fan. Thus, the pollution level below the jet fan must be higher than the other area.

Cited by 0 works.

Authors