해수 유동층 여과시스템의 적정 운용 조건

손맹현, 조기채, 전임기 et al. · 한국양식학회지 · 2005

Experiments were conducted to examine the differences in ammonia removal rates with the different filter media between sand and zeolite, the expanding rates between 50% and 100%, the water temperatures between 15℃ and 25℃, and the ammonia loading rates between 2 ㎎/L and 5 ㎎/L in the seawater fluidized bed filters system (FBF). The 2.1 m high FBF (8.3 ㎝ diameter) consisted of the clear acrylic for the upper half and a PVC pipe for the lower half. Sand and zeolite were used as the filter media in sizes of 0.5±0.1 ㎜. Each biofilter contained 5.4 L of media. The ammonia removal rates of the biofilter were higher at the 25℃ water temperature than those of the biofilter at 15℃ water temperature, and higher at the 50% expanding rate of filter media than those of the biofilter at 100% expanding rate of filter media. Also, the ammonia removal rates of FBF were higher at 5 ㎎/L ammonia concentration than those of FBF at 2 ㎎/L ammonia concentration in rearing water. With these better conditions the ammonia removal rates of FBF per day are practically acceptable and ranged from 80.6 to 210.6 g/㎥.

Cited by 0 works.