소규모 다중이용시설에서의 공기청정기 현장적용 성능평가

곽호찬, 정윤영, 김종철 et al. · 한국생활환경학회지 · 2009

In this study, evaluated removal efficiency of indoor air pollutants such as PM₁? (particulate matter), TBC (total bacteria colony), HCHO (formaldehyde), TVOC (total volatile organic compound) by using air cleaner in smallsized crowd facilities. As the results, the removal efficiency of PM₁? and TBC were shown as 58% and 70%. And also HCHO and TVOC were shown as 60%, 70%. The statistic result of correlation analysis between incipient PM₁? concentration (no-air cleaner) and after 3 days (apllied air cleaner) PM₁? concentrations were significantly shown as correlated. And the result of correlation analysis between incipient TBC, HCHO, TVOC concentrations (no-air cleaner) and after 3 days TBC, HCHO, TVOC concentrations (appllied air cleaner) were significant shown as correlated. In these results, we suggest that air cleaners applied on small-sized crowd facilities can help to reduce of indoor air pollutants as effectively