유기랭킨사이클 시스템의 운전 특성에 관한 실험적 연구
엄홍선, 윤천석, 김영민 et al. · 대한설비공학회 하계학술발표회 논문집 · 2012
To understand operating characteristics of ORC(Organic Rankine Cycle) system, apparatus is made and experimental study is performed. In the range of power output for small scale ORC system from 1 to 10 kW, the scroll expander is a good choice for its performance and reliability. In this study, some experimental tests of ORC system equipped with scroll expander are carried out. To investigate the effects of various operating conditions such as expander speed and mass flow rate of R-134a for expander inlet temperature from 100 ℃ to 200 ℃, thermal power, thermal efficiency and expansion efficiency are selected as main parameters for the performance of the system