루프 써모사이폰의 작동특성과 열전달 한계 연구
강환국, Myoung Soo Kim, 정환수 et al. · 대한기계학회 춘추학술대회 · 2001
The loop type thermosyphon has been designed and tested for cooling several hundreds watt of heat from thermo-electric modules. This cooling system is consisted of copper block, condenser which is fabricated with tubes and fins and transport lines. In this research, operational characteristics and limitation of the loop thermosyphon were investigated as a function of fill charge ratio, thermal load, vapor temperature and effective head. The experimental results shows that the heat transport limitation is dominated by vapor temperature and effective head. The evaporating heat transfer coefficient is affected by vapor temperature and heat flux, but the fill charge ratio and liquid head is minor factor.