〈학술논문〉고온초전도 전력케이블용 극저온냉각시스템 개발현황

염한길, 고득용, 박성제 et al. · 대한기계학회 춘추학술대회 · 2011

Cryogenic cooling is necessary for HTS power cables to perform their intended function. In the cooling process, sub-cooled liquid nitrogen is circulated by a pump to absorb and dissipate the heat generated in the cable and introduced from outside. For successful cooling, the thermal loads of cable systems and the hydraulic characteristics of the cooling passage of the cable should be well investigated to design the long length cables. The cooling capacity of the cable system is decided by evaluating the thermal load. The pressure drop in the cable is an important design parameter, because the pressure drop decides the length of the cable, size of the coolant circulation pump and circulation pressure, etc. Recently, demonstrative and practical researches of the HTS power cable and the cryogenic system are has been actively going. In this paper, the domestic and international current state of this field is described.

Cited by 0 works.