열병합발전소 가스터빈 압축기 회전익 손상 원인 분석

강명수, 윤완노, 정남근 et al. · 대한기계학회 춘추학술대회 · 2010

The vibration increased suddenly during the normal operation of the gas turbine in cogeneration plant. The subsequent disassembly showed one blade of compressor 5th stage fractured and many downstream blades were damaged. The OEM redesigned and replaced the 5th blades already, because the 5th blade failure had occurred before. Optical microscope and scanning electron microscope inspection of the blade which had the same indication by the non-destructive test showed the forging defect at the same location with the fractured blade. The forging defect might be induced by the insufficient removal of surface crack and scale or foreign object inclusion in the process of hot forging. The defect existed at the highly stressed area and the crack initiated at the point. And the crack propagated by the high cycle fatigue and fractured finally. This paper describes the root cause analysis and countermeasures for the gas turbine compressor blade damage of the cogeneration plant.