건물외피에 적용한 자연형 태양열 시스템의 성능 분석

윤태균, 이현수, 서승직 · 대한건축학회 학술발표대회 논문집 - 계획계 · 2011

Energy consumption in construction sector is gradually increasing. Building envelope is the most weak part in the energy loss. In this study, A combined passive solar system of direct-gain(curtain wall) and indirect-gain(Trombe wall) was applied to the envelope of the south facade by means of reducing energy loss through building envelope. To conduct this study, unsteady state of energy balance equations was discretized by Finite-difference method and Temperature and heat flow of each surface in winter were calculated by using numerical simulation program. The results will indicate that the CSS(Combined Solar System) indeed perform better than the reference system in thermal comfort zone

Cited by 0 works.