시멘트 종류를 변화시킨 프리캐스트 고강도 콘크리트의 온도특성에 관한 실험적 연구
김성진, 박흥이, 박현 et al. · 대한건축학회 논문집 - 구조계 · 2009
As architectures have recently become high-risers and mega-structured, stable high strength products have been ensured. Accordingly, use of precast concrete accouplement has been increased in order to facilitate air compression and rationalize construction. Since external rising by the steam heating and internal rising by the accumulation of cement hydration heat for the temperature of members, precast concrete members with large cross-section used for high-rise mega-structure's columns and beams may exhibit different temperature history compared to the precast concrete members for wall and sub-floor with relatively small cross-sections. Therefore, this study aims to elucidate the characteristics of temperature history of mass concrete members cast with high-strength concrete for precast concrete application. In this study, large cross-sectional precast concrete mock-up, unit cement quantity, and temperature histories in manufacturing precast concrete member under different curing condition were inclusively investigated. Consequently this research is about the factors of different hydration temperature between the test specimen, typically used in strength management method of concrete, and the mock-up model. We could find that it has a different face. The highest temperature, temperature increment and gradient.
Cited by 0 works.