선박 내 폐열 회수 시스템 구성을 고려한 유기 랭킨 사이클의 열역학적 분석

이동길, 진정근, 이호기 et al. · 대한기계학회 춘추학술대회 · 2012

The present work focuses on the heat transfer loop of Organic Rankine Cycle - Waste Heat Recovery System (ORC-WHRS) for the vessel. The heat transfer loops were evaluated based on the power output of thermal cycle. Performances of ORC were calculated at the different temperature conditions of thermal loop. Calculated results were compared in terms of cycle and system efficiency. The result shows additional electricity of Maximum. 660㎾e can be produced by using ORC-WHRS, and the system has 9~13% of cycle efficiency depends on the heat transfer loop design and pinch condition of heat exchanger. In this work shows, ORC-WHRS can produce 60~73% of required electricity of Suez-max COT at the normal operation running condition and this lead to fuel saving effect.

Cited by 0 works.